| Sector | abcEducation And Research Institute | Tender Value | INR 2.01 Lakhs approx. | Location | Kerala - India | Ref.No | 70622021 | Closing Date | 02 - Apr - 2024 | | | School of Chemical Science Renovation of Seminar Hall - Electrical Works "supply and Wiring Points According to is 732-1989 Using Rigid Pvc Conduit of Minimum Size 20 Mm with Specials Conforming to is 9537 Part Iii 1983 and with Suitable Size Specials Conforming to is 3419-1988, , Fixing the Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably and with 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650v Grade, Including Providing Switch Board Main and Continuous Earthing with No.14 Swg Bare Copper, required Quantity of, Copper Earth Socket, Brass Bolt and Nut Crimping/ Soldering Etc Complete with Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (white) Etc. Up to and Including 6a Modular Type Sp, Switches and Making Good the Surface of Wall, Colour Washing Etc. Complete. All the Terminations in the Switch Boards and Db's Shall Be Tinned and the Wires Shall Be Drawn and Fixed Along the Periphery of the, Box Using Suitable Ties, Tie Mounts Etc as Required. (rohs Compliant Modular Accessories).single Control Light Point with 6a, Plate Ceiling Rose - Short Point", "supply and Wiring Points According to is 732-1989 Using Rigid Pvc Conduit of Minimum Size 20 Mm with Specials Conforming to is 9537 Part Iii 1983 and with Suitable Size Specials Conforming to is 3419-1988, , Fixing the Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably and with 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650v Grade, Including Providing Switch Board Main and Continuous Earthing with No.14 Swg Bare Copper, required Quantity of, Copper Earth Socket, Brass Bolt and Nut Crimping/ Soldering Etc Complete with Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (white) Etc. Up to and Including 6a Modular Type Sp, Switches and Making Good the Surface of Wall, Colour Washing Etc. Complete. All the Terminations in the Switch Boards and Db's Shall Be Tinned and the Wires Shall Be Drawn and Fixed Along the Periphery of the, Box Using Suitable Ties, Tie Mounts Etc as Required. (rohs Compliant Modular Accessories).single Control Ceiling Fan Point with 6 a, 3 Plate Ceiling Rose & with Socket Size Stepped Electronic Regulator. - Short Point", Supply and Wiring Points According to is 732-1989 Using Rigid Pvc Conduit of Minimum Size 20 Mm with Specials Conforming to is 9537 Part Iii 1983 and with Suitable Size Specials Conforming to is 3419-1988, Fixing the Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably and with 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650v Grade, Including Providing Switch Board Main and Continuous Earthing with No.14 Swg Bare Copper, required Quantity of Copper Earth Socket, Brass Bolt and Nut Crimping/ Soldering Etc Complete with Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (white) Etc. Up to and Including 6a Modular Type Sp Switches and Making Good the Surface of Wall, Colour Washing Etc. Complete. All the Terminations in the Switch Boards and Db's Shall Be Tinned and the Wires Shall Be Drawn and Fixed Along the Periphery of the Box Using Suitable Ties, Tie Mounts Etc as Required. (rohs Compliant Modular Accessories).combined Plug Point with 6 a, 5 Pin Plug Socket Controlled By 6 a, Switch in the Same Switch Board as That of Light Points, "supply and Fixing of Following Sizes of Light Gauge Pvc Conduit Along with Accessories in Surface/ Recess, Including Cutting the Wall and Making Good the Same in Case of Recessed Conduit as Required20 Mm", Supply and Fixing of Following Sizes of Light Gauge Pvc Conduit Along with Accessories in Surface/ Recess Including Cutting the Wall and Making Good the Same in Case of Recessed Conduit as Required25 Mm, Supply and Drawing 650/1100 V Grade Frls Pvc Insulated Stranded Single Core Copper Conductor Cables Conforming to is 694 Part I 1990 in the Existing Surface / Recess Conduit as Required Including Giving Necessary Connections of the Following Sizes.1.00 Sq.mm 2 Run, Supplying and Drawing Following Sizes of Frls Pvc Insulated Copper Conductor, Single Core Cable in the Existing Surface / Recessed Steel/ Pvc Conduit as Required.3 X 1.5 Sq.mm, Supplying and Drawing Following Sizes of Frls Pvc Insulated Copper Conductor, Single Core Cable in the Existing Surface / Recessed Steel/ Pvc Conduit as Required.3 X 2.5 Sq. Mm, Supplying and Drawing Following Sizes of Frls Pvc Insulated Copper Conductor, Single Core Cable in the Existing Surface / Recessed Steel/ Pvc Conduit as Required.3 X 4 Sq. Mm, Supplying and Drawing Following Sizes of Frls Pvc Insulated Copper Conductor, Single Core Cable in the Existing Surface / Recessed Steel/ Pvc Conduit as Required.5 X 4 Sq. Mm, Supply & Fixing the Following Types/ Sizes of Boxes Suitable for Modular Accessories in Surface/ Recess Including Making Good the Damages, Colour Washing Etc as Required (rohs Compliant )2 Modul |
|
|
If you are a new user, then please
register, it's Free and then fill the form below.
If you are registered with us, just fill the form below, we will get back to you
shortly.
|
All fileds marked with '*' are compulsary.
|
|
|